 AHR - Wet Tap, Low Pressure (2" to 36")
Wet-tap, low pressure model used on liquid, air, and gas. For liquids without system shutdown.
Ratings
Insertion/Removal:
- Pressure; 75 PSI (5 Bar) maximum
- Temperature; 150 °F (66 °C) maximum
Operating:
- Pressure; 150 PSI (10 Bar) maximum
- Temperature; 150 °F (66 °C) maximum
Standard Components
- T-Type head, 316 SS 1/4" or 1/2" FNPT connection
- CS compression fitting with SS ferrule
- 316 SS isolation ball valve, NPT
- CS reducer coupling
- CS 3000 lb weld fitting ASTM Al05
- CS nipples, schedule 40
- 316 SS Ellipse® sensor
- 316 SS ID tag with wire
- Instrument valves (2 per sensor) 1/4" or 1/2", CS
Options
- Double support, CS or 316 SS (only with system shutdown)
- Compression fitting - all 316 SS
- Weld fitting - 316 SS 150 lb or 3000 lb
- 316 SS cage nipple
Product Brochure (PDF - 3.1 MB)
Technical Specifications (PDF - 224 KB)
Instruction Manual (PDF - 430 KB)
|